idNite Solar offers a range of PV Combiners to accommodate PV systems as small as a two string off grid cabin and up to 16 strings for a 100KW commercial grid tie inverter. The MNPV series of combiners are the result of 20 years of design and manufacturing experience in the renewable energy industry. Each unit has the same quality features such as:

  • Aluminium rainproof type 3R enclosure

  • Internal plastic injection molded dead front covers

  • Knock outs that accept waterproof strain reliefs, conduit or panel mount MC type connectors

  • Knock outs for lightning arrestors

  • Uses 150VDC & 300VDC breakers or 600VDC fuses depending on model number

  • Adaptable for two separate inverters or charge controllers on certain models




MNPV3       MNPV6     MNPV6-250     MNPV12     MNPV12-250     MNPV16     MNPV6-DISCO

 


        

Specs

MNPV3 For 150 VDC charge controllers and 600 VDC gridtie inverters

Gray aluminium type 3R rainproof enclosure with insulating deadfront, will accept three 150VDC (MNEPV) breakers or two 600/1000 VDC fuse holders. Includes a 60 amp plus bus bar, 6 position PV negative bus bar and a 6 position ground bus bar. Punch out tabs on the plastic deadfront make for a clean installation using circuit breakers. An included snap in adapter makes for a professional looking installation when installing fuse holders. A single 300VDC breaker from 7 to 50 amps may be installed as a disconnect (no combining busbar) . The enclosure may be mounted to a pole or wall indoors or out.

Breakers/fuse holders sold separately

 


  


Specs

MNPV6 For 150 VDC charge controllers and 600 VDC gridtie inverters

Gray aluminium type 3R rainproof enclosure with insulating dead front, will accept six 150VDC breakers or four 600/1000VDC fuse holders. Includes 15 position PV negative bus bar, 14 position ground bus bar, 120 amp Plus bus bar for breakers and 80 amp bus bar for fuses. Punch out tabs on the plastic deadfront make for a clean installation using circuit breakers. An included snap in adapter makes for a professional looking installation when installing fuse holders. Up to three 300VDC breakers from 7 to 50 amps may be installed as a disconnect (no combining busbar) . The enclosure may be mounted to a pole or wall indoors or out. The plus bus bar may be split to support two grid tie inverters or two charge controllers. Gridtie inverters typically can have PV minuses common. Most charge controllers can have PV minuses common.

Breakers/fuse holders sold separately

 



  


Specs

MNPV6-250 For 200 and 250 VDC charge controllers

Gray aluminium type 3R rainproof enclosure with insulating dead front, will accept three x 300 VDC breakers. Includes 15 position PV negative bus bar, 14 position ground bus bar, 120 amp Plus bus bar for breakers and 80 amp bus bar for fuses. Punch out tabs on the plastic deadfront make for a clean installation using circuit breakers. An included snap in adapter makes for a professional looking installation when installing fuse holders. Up to three 300VDC breakers from 7 to 50 amps may be installed as a disconnect (no combining busbar). The enclosure may be mounted to a pole or wall indoors or out.

Breakers/fuse holders sold separately.

 



  


Specs

MNPV12 For 150 VDC charge controllers and 600 VDC gridtie inverters

Gray aluminum type 3R rainproof enclosure with insulating dead front, will accept twelve 150VDC breakers or ten 600/1000VDC fuse holders. Includes 15 position PV negative bus bar, 15 position ground bus bar, and two 200 amp Plus bus bars for breakers or fuses. Plus busbars can be combined or separated to support 2 grid tie inverters or two charge controllers. Charge Controllers and Gridtie inverters can typically can have a common PV minus. The exception is the XW and BlueSky. Snap in adapters are included for use with fuse holders for a professional fit and finish.

Breakers/fuse holders sold separately.

 




  


Specs

MNPV12-250 For 200/300 VDC charge controllers

Gray aluminium type 3R rainproof enclosure with insulating dead front, will accept six 300VDC breakers. Includes 15 position PV negative bus bar, 15 position ground bus bar, and two 168 amp Plus bus bars for breakers. Plus busbars can be combined for six strings or separated to support 2 high voltage charge controllers with 3 strings each. PV negative busbar is common when splitting the Plus bus bar into two systems. The MidNite Classic can use common PV negatives.

Breakers/fuse holders sold separately

 

  


Specs

MNPV16 For up to 100,000 watt 600 VDC grid-tie inverters

Gray aluminium type 3R rainproof enclosure with insulating dead front, will accept sixteen 600/1000 VDC fuse holders. Includes 21 position PV negative bus bar, 18 position ground bus bar, and 240 amp Plus and Minus busbars. Plus bus bar cannot be split into multiple systems.

Breakers/fuse holders sold separately

 






  


Specs

MNPV6 Disco combiner is designed for combining PV strings up to 150VDC 120 amps total output

Applications:

  • PV combiner up to six strings using MNEPV 150 VDC breakers

  • DC load center using MNPV breakers


Features:

  • Convenient disconnect handle

  • All aluminium powder coated housing that won’t rust

  • Flip up cover that can stay in the open position during installation

  • PV Negative bus bar with 14 useable openings  

  • Chassis ground bus bar with 14 useable openings  

  • Standard din rail to mount up to 6, 150V or 3, 300 Volt breakers

  • 120 Amp tin plated copper bus bar to combine breaker outputs - bus bar may be split in two

  • Dead front cover snaps into place after wiring is complete for safety

  • Knockouts for PV in and PV out on bottom and sides

  • Top surface is available to bring conduit in from directly above the enclosure

 


            

 